Handling
Lift unit fans by the lifting holes or by the shipping
container. Never lift by the housing.
Storage
If the fan is stored for any length of time prior to
installation, store it in its original shipping crate and protect
it from dust, debris and the weather.
Rotate the wheel several revolutions every three to ve
days to keep a coating of grease on all internal bearing
parts.
®
This installation manual provides information for
installing and conguring the Loren Cook Company HMD.
Models: HMD-2400, HMD-3400, HMD-4100.
For information and instructions on special equipment,
contact Loren Cook Company.
For additional safety information, refer to AMCA
publication 410-96, Safety Practices for Users and
Installers of Industrial and Commercial Fans. This
document and all Cook publications may be obtained from
Cook by phoning (417) 869-6474, extension 166; by FAX
at (417) 832-9431; or by e-mail at [email protected].
All Cook publications are available on LorenCook.com.
Receiving and Inspection
Carefully inspect the unit and accessories for any
damage and shortage immediately upon receipt of the unit.
Turn the blower by hand to ensure it turns freely and
does not bind.
Record on the Delivery Receipt any visible sign of
damage.
HMD
Heated Makeup Direct: A Direct Fire Make-Up Air Unit
Installation, Operation, And Maintenance Manual
WARNING: Improper installation,
adjustment, alteration, service or
maintenance can cause property damage,
injury or death. Read the installation,
operating and maintenance instructions
thoroughly before installing or servicing this
equipment.
FOR YOUR SAFETY
If you smell gas:
1. Open windows.
2. Don’t touch electrical switches.
3. Extinguish any open ame.
4. Immediately call your gas supplier.
FOR YOUR SAFETY
The use and storage of gasoline or other
ammable vapors and liquids in open
containers in the vicinity of this appliance is
hazardous.
Lifting
holes
Fire Or Explosion Hazard
Installation and service must be performed
by a qualied installer, service agency or
gas supplier.
Intake Air
If HMD unit is used for make-up air for any
type of fuel burning equipment, HMD unit
must NOT be primary source of intake air.
Consult fuel burning equipment manufacture
for requirements and recommendations.
Environmental Hazards
Other considerations may be required if high
winds or seismic activity are present. If more
information is needed, contact a licensed
professional engineer before moving
forward.
Improper installation, adjustment, alteration,
service or maintenance can cause serious
injury, death or property damage. Carefully
read this publication and any supplemental
documents prior to any installation or
maintenance procedure.
Vue de la page 0
1 2 3 4 5 6 ... 15 16

Résumé du contenu

Page 1

1HandlingLift unit fans by the lifting holes or by the shipping container. Never lift by the housing.Storage If the fan is stored for any length of ti

Page 2 - Installation

10TroubleshootingNoNoNoNoNoNoIs the air volume too high?Adjust drive to reduce rpm as needed.Adjust drive & increase external pressure. as needed.

Page 3

11Troubleshooting Insufcient airowNoNoNoNoNoNoAre the dampers not fully open? This may take several minutes.Adjust dampers or replace damper/actuato

Page 4 - Operation

12TroubleshootingIs the blower speed too high?Are the lters missing?Is there insufcient external pressure?YesYesYesAdjust drive & decrease exter

Page 5

13Excessive noise or vibrationNoNoNoNoIs the belt loose or damaged?Clean or replace the wheel.Align sheaves.Lubricate or replace bearings as needed.Cl

Page 6 - Maintenance - All year

14Heater does not attempt to light. Heater attempts to light, but no ameNoNoNoReplace 24 VAC transformer.#bCorrect / replace high temp overload switc

Page 7

15Attempts to light, with visible spark, but no ame TroubleshootingNoNoNoNoCheck the supply gas pressure and compare it with the unit’s nameplate pre

Page 8 - CFM / Static Pressure chart

16Service ContactsDealerInstallation Contractor:Service Contractor:Date of Installation:Corporate Ofces 2015 E. Dale Street Springeld, MO 65803Phon

Page 9

2Hanging Mount ExampleHangersSealantUnit SupportsDuctWiring EntryInstallationClearance to Combustible / Service ClearancesThe minimum distance require

Page 10 - Troubleshooting

3attached to the unit. 8. Using an appropriate sealant, seal the seam between the weatherhood and the unit.WiringAll wiring should be done in accorda

Page 11 - Insufcient airow

4holes.3. Connect the main power lines to the disconnect switch and main grounding lug(s). Torque eld connections to 20 in.-lbs.4. Wire the optiona

Page 12

5may be experienced during the initial start-up. Left unchecked, it can cause a multitude of problems including structural and/or component failure. G

Page 13

6left to right. Use a screw driver on top of modular gas valve. While monitoring the unit’s temperature rise, set the maximum ring rate by adjusting

Page 14

7size. The instructions provided in this manual and those provided by the bearing manufacturer will minimize any bearing problems.Lubricate bearings p

Page 15

8Do not enlarge burner ports when clearing a blockage, performance could be affected.Replace or tighten any loose or missing fasteners on the mixing p

Page 16 - Warranty

9NoNoNoNoNoIs the proper power supply at the main disconnect?1. Compare the supplied voltage, hertz, and phase with the motor’s nameplate information.